FEATURES Housing Cylindrical thread design Housing Standard Thread size M12 x 1 Diameter Ø 12 mm Sensing range Sn 4 mm Installation type Non-flush Switching frequency 2, 000 Hz Connection type Male connector M12, 4-pin Switching output PNP Output function NO Electrical wiring DC 3-wire Enclosure rating IP67 1) MECHANICS/ELECTRONICS Supply voltage 10 V DC... 30 V DC Ripple = 10 % Voltage drop = 2 V 1) Current consumption 10 mA 2) Time delay before availability = 100 ms Hysteresis 5 %... 15 % Reproducibility = 2 % 3) 4) Temperature drift (of Sr) ± 10 % EMC According to EN 60947-5-2 Continuous current Ia = 200 mA Short-circuit protection? Reverse polarity protection? Power-up pulse protection? Shock and vibration resistance 30 g, 11 ms/10 Hz.
.. 55 Hz, 1 mm Ambient operating temperature –25 °C... +75 °C Housing material Metal, Stainless steel V2A ( 1.4305 ) Sensing face material Plastic, PA 66 Housing length 65 mm Thread length 43 mm Tightening torque, max. = 12 Nm UL File No. NRKH. E181493