Your Browsing History
Meet Your Seller
VEVEL 48V 2.5A 120W Single Output Industrial DIN Rail Power Supply DR-120-48
Limited time offer, ends 09/20 By Cookvio
- DC output range:48V,2.5A; Output voltage accuracy:+1%; Ripple 100mV; Efficiency 85%; Input voltage range:switch from 90 to 132VAC/180 to 264VAC or 248 to 370VDC.
+
+
Overview
Reviews
DC output range: 48V, 2.5A
Output voltage accuracy: +1% Ripple 100mV Efficiency 85%
Input voltage range: switch from 90 to 132VAC/180 to 264VAC or 248 to 370VDC.
Input surge current: cold start 40A/230V
Voltage adjustment range:
12V: 12~14V, 24V: 24~28V, 48V: 48~53V
Overload protection: over current point at 105%~150%constant current limit current automatic recovery.
Overvoltage protection: when the rated output voltage is 115%to 142%, turn off and reset.
Overheat protection: 90+5 (TSW1 detects the radiator temperature of the power transistor).
Protection type: overheat shut off, automatic recovery after the temperature drops
Start up hold time: 230VAC load 500ms, 70ms, 36ms
Insulation characteristics: input
and output: 3KVac, input
and shell: 1.5KV ac, output
and shell: 0.5KV ac, 1 minute
Working temperature: -10~+60 C (see output load drop curve)
Aseismic mobility: 10~500Hz, 2G 10 minutes/cycle, XYZ axis 60 minutes each.
Safety certification: through UL508, TUV EN60950-1 UL60950
certification EMC standards: EN55011, EN55022 (CISPR22), EN61204-3 class B, harmonics: EN61000-3-2, -3
EMC Standard:
Anti-interference: EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, ENV55024, EN61000-6-2(EN50082-2), Class A Heavy Industry Standard The mean time to failure is more than 136 thousand and 800 hours, MIL-HDBK-217F (25 C).
Connection mode: input
port: 3 point.
Output: 4 point screw DIN terminal
Output voltage accuracy: +1% Ripple 100mV Efficiency 85%
Input voltage range: switch from 90 to 132VAC/180 to 264VAC or 248 to 370VDC.
Input surge current: cold start 40A/230V
Voltage adjustment range:
12V: 12~14V, 24V: 24~28V, 48V: 48~53V
Overload protection: over current point at 105%~150%constant current limit current automatic recovery.
Overvoltage protection: when the rated output voltage is 115%to 142%, turn off and reset.
Overheat protection: 90+5 (TSW1 detects the radiator temperature of the power transistor).
Protection type: overheat shut off, automatic recovery after the temperature drops
Start up hold time: 230VAC load 500ms, 70ms, 36ms
Insulation characteristics: input
and output: 3KVac, input
and shell: 1.5KV ac, output
and shell: 0.5KV ac, 1 minute
Working temperature: -10~+60 C (see output load drop curve)
Aseismic mobility: 10~500Hz, 2G 10 minutes/cycle, XYZ axis 60 minutes each.
Safety certification: through UL508, TUV EN60950-1 UL60950
certification EMC standards: EN55011, EN55022 (CISPR22), EN61204-3 class B, harmonics: EN61000-3-2, -3
EMC Standard:
Anti-interference: EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, ENV55024, EN61000-6-2(EN50082-2), Class A Heavy Industry Standard The mean time to failure is more than 136 thousand and 800 hours, MIL-HDBK-217F (25 C).
Connection mode: input
port: 3 point.
Output: 4 point screw DIN terminal
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
- CONTACT
Return Policies
- Return for refund within: 30 days
- Return for replacement within: 90 days
- This item is covered by Cookvio Return Policy
Manufacturer Contact Info
- For a directory of all our manufacturers, please click below.
- Manufacturers Directory