ETCR9150B Wireless H//L Voltage Clamp Current Meter AC 0mA~1200A CT Size F36mm
Notice:
The standard package don't include batteries.Because,the international air shipping forbid to ship liquid,powder and batteries,we can not put them in the package box.Hope you can understand buy them in your local store or supermarket.
At the same time, please forgive us that we are unable to provide the English user manual. If you need it, please contact the customer service after purchase.
Thanks for your support!
Product Main Function
High/low voltage AC current measurement (operate with insulation rod above 600V).
Measure Range : AC 0mA~1200A
Max Resolution : 1mA
Data Storage : 99 groups
Line Voltage : Bare wire test below110kV
CT Size : F36mm
ETCR9150B wireless H//L voltage clamp current meter break through the traditional structure, well-designed and manufactured for measuring high voltage current , adopts CT technology and digital integration technology, the instrument is composed of special clamp current meter and high voltage insulating rod, The B type - wireless transmission test data, equipped with wireless receiver, can receive the measured data within straight distance 30 meters .If not use insulation rod, which can be used as high accuracy low voltage clamp current meter.
Range and Accuracy
Test Function Range Accuracy resolution
H/L Voltage AC Current Test 0mA~99.9A ±1%rdg±5dgt 1mA
100A~599A ±1%rdg±5dgt
600A~1200A ±2%rdg±5dgt
23?±5?, below 80%RH
Technical Specification
Function Description
Model ETCR9150B Wireless H/L voltage clamp current meter
Measure Range AC 0mA~1200A
Max Resolution 1mA
Measure Accuracy
(23?±5? ,Below 80%RH) 0mA ~ 99.9A : ±1%rdg±5dgt
100A ~ 599A : ±1.5%rdg±5dgt
600A ~ 1200A : ±2%rdg±5dgt
CT Size F36mm
Meter Dimension Detector: 297mm×119mm×58mm; Receiver:78mm×165mm×42mm
Meter Weight Total weight:3365g(include insulation rod)
Power Supply DC6V dry lithium battery(LR03X4PCS)
LCD Size 47mm×28.5mm
Sampling Rate 2 times / second
Communication Mode Wireless transmission, straight-line distance 30m
Data Hold In general test mode, press HOLD key to hold data, “HOLD” symbol display.
Data Storage 99 groups, in storage process “MEM” symbol display, “FULL” symbol flash display indicate storage is full
Data Access “MR” symbol display, it can look over all the stored data
Overflow Display Exceed measurement range overflow function: “OL A” symbol display
Automatic Shutdown 15 minutes after boot up, the meter shuts down automatically without any operation, to reduce battery consumption
Battery Voltage When battery voltage is lower than 4.8V, low battery voltage symbol “ ” display and remind to replace battery.
Line Voltage Bare wire test below110kV (Operate with insulation rod, the telescopic insulation rod is completely opened)
Insulation Rod Size F32mm, 1mX5 section
Insulation Rod Withstand Voltage 110KV
Accessories Clamp meter: 1PCS; Receiver: 1PCS; Insulation rod: 5PCS; Instrument bag: 1PCS