ETCR1000A Non Contact 3 Phase Rotation Tester Indicator Detector
Product Features:
ISO, Patent & CE certificate
OEM services available
Function: phase detection (positive/negative)
Display: LED
Dimension (mm): 70*75*30
Weight(g): 270
Continuously using 200 hours
Meets IEC-10101 (EN61010) ,CAT III (600V) safety requirement
Electricity range: AC60~600V,40 Hz~70Hz( continuous sine wave input )
The highest detected voltage: AC600V
Insulating Strength: 5.4kVrms
Safety suitable for: 100Mva
Introduction
This is a phase detector, designed to perform phase sequence checks and live line checks of a 3-phase circuit using a static induction voltage clip.
The static induction voltage clips are used to be able to clip on a cladded wire.
It is small with a CAT 600V safety rating.
Red LED lamps are used to make the indication visible in dimly lit areas.
The direction of phase sequence can be checked easily using the LED lamps, which blink in order.
. Specifications
1). Basic Specifications
Function Phase detection (positive/negative)
Voltage detection method Static induction
Object to be connected Insulated wire (nominal sectional area of the conductor: 2 to 120mm2,
finished outer diameter: up to 17mm)
Performance-guarantee voltage range 3-phase, 70V to 600 VAC (sine wave,continuous)
Operating frequency range 45Hz to 66Hz
2). Display
Phase-detection
indication Positive phase sequence:
The four phase-sequence lamps blink order (clockwise) and the buzzer sounds intermittently.
Negative phase sequence:
The four phase-sequence lamps blink in order (counterclockwise) and the
buzzer sounds continuously.
Line-voltage indication R-S lamp, S-T lamp
Power indication Power ON lamp: lights up (Power ON)
blinks (Battery Low)
3). General Specifications
Operating temperature and humidity -10 to 40(32 to 104), 80%RH or less ( with no condensation)
Storage temperature and humidity -20 to 60 (-4 to 140), 80%RH or less (with no condensation)
Location for use Altitude up to 2000m(6562 feet), indoors
Maximum rated voltage to earth 600V
Dielectric strength 5.4kVrms
Power supply Rated supply voltage 1.5VDC×2 Two AA size batteries
Maximum rated power 300mVA
Continuous operating time* Approx.70 hours(Power ON, Standby state, using R6P manganese battery)
*Battery life
Auto Power Off
(This function can not Be canceled.) The power will be turned off automatically if the Instrument remains idle
for 15 minutes after the power is turned on. To reset, turn the power on
again using the Power ON switch.
Options Carrying case, Strap*, Spiral tube*, Instruction manual, *Attaching as the occasion demands.(Battery does not include)
Cable length Approx. 0.7m
Dimensions and mass Approx. 70W×75H×30Dmm(2.76W×2.95H×1.18D)
(excluding projections), Approx. 200g(7.1oz)
Applicable standards Safety EN61010-1:2001,EN61010-031:2002
Pollution degree2, Measurement category CAT III(600V)(anticipated
transient overvoltage 6000V)
EMC EN61326:1997+A1:1998+A2:2001
Packing Phase Detector: 1 piece; strap: 1 piece; Carrying Case: 1 piece