Tripp Lite Metered PDU with ATS, 2.9 kW Single-Phase 120V Outlets (24 x 5-15/20R, 1 x L5-30R), 2 x L5-30P, 2 x 10 Feet Cords, 2U Rack-Mount, TAA (PDUMH30AT)
Single phase 30A 120V Auto Transfer Switch / ATS PDU; Highly reliable Solid State Switching
Separate primary & secondary inputs connect to any two compatible power sources
2U horizontal rackmount; 2 x L5-30P inputs; 24 x 5-15/20R & 1 x L5-30R outlets
Digital meter reports voltage, kW load level and output amperage in 4 load segments
TAA-Compliant
+
+
Overview
Specs
Reviews
Learn more about the Tripp Lite PDUMH30AT
Model
Brand
Tripp Lite
Model
PDUMH30AT
Details
Type
Switched, Metered
Rack Size
2U
Style
Rackmount
Front Panel LEDs
Primary and Secondary input connection. Digital current meter display shows the amount of power consumption in amps for entire PDU output.
Certifications
Tested to UL 60950 (USA, Canada), Class A (Emissions), NOM (Mexico), RoHS Complaint
ROHS
Yes
Input
Input Voltage
100V, 120V, 127V
Maximum Input Current
30A
Input Connector(s)
NEMA L5-30P
Cord Length
10 ft.
Output
Output Voltage
100V, 120V, 127V
Output Frequency
60Hz
Output Connector(s)
24 x 5-15/20R & 1 x L5-30R outlets
Overload Protection
2 x 20A output breakers protect 12 x 5-15/20R outlets each
Environmental
Operating Elevation
0 - 10,000 Feet (0 - 3000 m)
Storage Temperature
-15 to 50 degrees Celsius
Storage Relative Humidity
5-95% non-condensing
Feature
Features
120V 30A Automatic Transfer Switch (ATS) / Metered PDU (Power Distribution Unit), Agency de-rated to 24A continuous
Provides a redundant power option for critical networking equipment with a single input power cord
2 digit display with segment selection button reports output power consumption in amps for four output segments (Segment 1: 12 x 5-15/20R outlets / Segment 2: 12 x 5-15/20R outlets / Segment 3: L5-30R outlet / Segment 4: total output of all outlets combined)
2U horizontal rackmount form factor; 12.50" depth
25 outlets (24 x 5-15/20R, 1 x L5-30R)
Set of two 10 Feet NEMA L5-30P input line cords enable separate PRIMARY and SECONDARY input connections
ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)
Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
Super-fast switchover between primary and secondary power sources occurs in 3 - 6 milliseconds
Front panel LEDs confirm power availability on both input lines