Your Browsing History
Best Sellers
- $619.70
- + FREE SHIPPING
- $595.22
- + $37.06 Shipping
- $645.96
- + FREE SHIPPING
Tripp Lite PDU ATS / Metered 120V 1.44kW 15A 8 5-15R Dual 5-15P 12ft Cords
- Single phase 15A 120V Auto Transfer Switch / ATS PDU
- Enables redundant A/B power option for single-corded network devices
- Separate primary & secondary inputs connect to any two compatible power sources
- 1U horizontal rackmount; 2NEMA 5-15P inputs; 8 NEMA 5-15R outlets
- Two digit visual current meter reports equipment load in amps; Upgrade options available
- TAA Compliant
+
+
Overview
Specs
Reviews
PDU ATS / METERED 120V 1.44KW 15A 8 5-15R DUAL 5-15P 12FT CORDS
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Limited Warranty period (parts): 2 years
- Limited Warranty period (labor): 2 years
- Read full details
Return Policies
- Contact Manufacturer for Assistance
- This item is covered by Newegg.ca's Manufacturer Only Return Policy.
- Read full return policy for details.
Manufacturer Contact Info
- Manufacturer Product Page
- Manufacturer Website
- Support Phone: 1-773-869-1111
- Support Website
- View other products from Tripp Lite
LOADING...
LOADING...
The Tripp Lite PDUMH15ATS is a 1U, 120V automatic transfer switch and metered PDU for network closets or racks that need A/B power-source redundancy for single-corded networking equipment. It has eight outlets and a digital load meter; continuous current is agency-rated at 12A.
Recommended For
- Small-office and branch-network operators powering single-cord routers, switches, or similar rack equipment from two separate power sources, who want the PDU to transfer the load if the primary source fails.
- Homelab builders with single-power-supply devices who already have two suitable power feeds or UPS-backed sources and want those devices covered by an automatic source switch.
- Rack administrators who need a local readout of the entire PDU’s current draw to check overall load, rather than per-outlet power monitoring.
- IT teams with single-cord equipment in a rack that need a practical fallback when a primary UPS or feed is taken out of service; community users describe ATS setups for this single-PSU use case.
Spec Summary
| Attribute | Value |
|---|---|
| Best For | Single-cord network equipment needing redundant A/B power input, rack-mounted power distribution, and load monitoring |
| Power Transfer And Monitoring | Automatic transfer switching between primary and secondary power sources, with a digital display reporting total output current in amps |
| Input And Output | 120V input at up to 15A (agency de-rated to 12A continuous); output options of 100V, 120V, or 127V at 50/60Hz, with rated power of 1.2kW, 1.44kW, or 1.52kW respectively; 8 NEMA 5-15R outlets |
| Power Cords And Sources | Two 12 ft input cords connect separate primary and secondary power sources; includes an attached NEMA 5-15P primary cord and a detachable C13-to-NEMA 5-15P secondary cord |
| Rack Mounting And Dimensions | 1U horizontal rackmount design; 1.75 × 17.50 × 14.50 in. and 11 lb |
| Certifications And Compliance | Tested to UL 60950-1, CSA certified, Class A emissions, NOM certified, RoHS compliant, and TAA compliant |
| Storage Conditions | Storage temperature: -15°C to +50°C; relative humidity: 5–95% |
| Model Identifiers | Tripp Lite PDUMH15ATS |