Tripp Lite Metered PDU with ATS, 15A, 8 Outlets (5-15R), 120V, 2 5-15P, 100 - 127 V Input, 2 12 ft. Cords, 1U Rack-Mount Power, TAA (PDUMH15AT)
- Single phase 15A 120 V Metered Power Distribution Unit (PDU) with Auto Transfer Switch (ATS)
- Enables redundant A/B power option for single-corded network devices
- Separate primary & secondary inputs connect to any two compatible power sources
- 1U horizontal rackmount; 2 NEMA 5-15P inputs; 8 NEMA 5-15R outlets
+
+
Overview
Specs
Reviews (5)
Tripp Lite's 120V 15A metered PDU system with Automatic Transfer Switching (ATS) is an 8 outlet PDU with a digital display to indicate total PDU power consumption in amps. Outlets are sequentially turned on at 250 milliscond intervals when the PDU is first energized from an unpowered state to prevent inrush-related equipment interaction on startup. Supports 1U rackmount installation in a 2 or 4 post rack. Included are 8 NEMA 5-15R outlets, and two 12 ft. 5-15P input power cord
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Limited Warranty period (parts): 2 years
- Limited Warranty period (labor): 2 years
- Read full details
Return Policies
- Contact Manufacturer for Assistance
- This item is covered by Newegg.ca's Manufacturer Only Return Policy.
- Read full return policy for details.
Manufacturer Contact Info
- Manufacturer Product Page
- Manufacturer Website
- Support Phone: 1-773-869-1111
- Support Website
- View other products from Tripp Lite
LOADING...
LOADING...
The Tripp Lite PDUMH15AT is a 15A, 120V metered 1U rackmount PDU with an automatic transfer switch, two NEMA 5-15P inputs and eight NEMA 5-15R outlets, suited to rack operators who need redundant power for single-corded network equipment.
Recommended For
- Network and IT teams supporting a rack, network closet, or small computer room who want a single-corded switch, router, or similar device to keep receiving power if its primary 120V source fails and a separate backup source is available.
- Homelab operators with rack-mounted AC equipment and two suitable power paths, such as separate UPS-backed sources, who want an ATS to feed single-power-supply devices.
- Rack operators who want to check total PDU current locally while distributing power to several 120V rack devices; the front-panel meter displays the combined load.
- Government or other TAA-focused IT buyers who need a 1U rack PDU for a 120V installation and can verify that this specific model meets their procurement requirements.
Spec Summary
| Attribute | Value |
|---|---|
| Best For | Providing redundant A/B power to single-cord network equipment in a 1U rackmount setup |
| Electrical Capacity | 15 A, 60 Hz; input and output voltage options are 100 V, 120 V, and 127 V. External listings report 1,520 W and a maximum/output rating of 1,800 W |
| Power Inputs And Outlets | Two NEMA 5-15P inputs and eight NEMA 5-15R outlets; dual input cords include one attached primary cord and one detachable secondary cord. The listed cord length is 12 ft |
| Automatic Transfer And Redundancy | Automatic transfer switch supports two 120 V AC power sources, with switchover in 2–7 ms, for redundant power applications; ATS use requires a full-time sine-wave online UPS |
| Monitoring And Controls | Front-panel ammeter displays current draw; eight LEDs show outlet power status and two indicate input power status. A card slot supports an optional SNMPWEBCARD for network monitoring and power-sequence configuration |
| Rack Fit And Construction | 1U rackmount metal enclosure; 1.75 × 17.50 × 14.50 in, 11.00 lb |
| Compliance And Safety | Tested to UL 60950-1; CSA and NOM certified; Class A emissions; RoHS and TAA compliant. External listing includes a California Proposition 65 warning identifying lead |
| Operating Environment | Relative humidity up to 95%, non-condensing |
| Model Identifiers | Tripp Lite PDUMH15AT |