Tripp Lite PDU3MV6L2120 Metered 0U 208V: C13 and C19 outlets / 120V: NEMA 5-15/20R outlets 16 6 ft 3-Phase Metered PDU, 5.7 kW, 48 Outlets, NEMA L21-20P Input Connection
- 208V: C13 and C19 outlets / 120V: NEMA 5-15/20R outlets
- 16
- 6 ft
+
+
Overview
Specs
Reviews
MAIN OVERVIEW FEATURES: Input Receptacles: NEMA L21-20POutput Receptacles: 36 x IEC 60320 C13,6 x IEC 60320 C19,6 x NEMA 5-15/20RInput Voltage: 230 V ACOutput Voltage: 120 V AC,208 V ACPower Rating (Watt): 5700 WMounting Orientation: VerticalPlacement: RackHeight: 70"Width: 1.9"Depth: 2.2"Weight (Approximate): 12.60 lbPackage Contents: Metered Rackmount PDUCord Retention BracketsRack Mounting BracketsUser ManualEnvironmentally Friendly: YesEnvironmental Certification: RoHSLimited Warranty: 2 Year
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Limited Warranty period (parts): 2 years
- Limited Warranty period (labor): 2 years
- Read full details
Return Policies
- Contact Manufacturer for Assistance
- This item is covered by Newegg.ca's Manufacturer Only Return Policy.
- Read full return policy for details.
Manufacturer Contact Info
- Manufacturer Product Page
- Manufacturer Website
- Support Phone: 1-773-869-1111
- Support Website
- View other products from Tripp Lite
LOADING...
LOADING...
The Tripp Lite PDU3MV6L2120 is a 0U, 3-phase metered rack PDU rated for 5.7 kW, with 48 outlets and built-in meters that report input current per phase. It suits data centers and densely equipped racks using a NEMA L21-20P 208V input.
Recommended For
- Data-center or server-rack operators with compatible 208V three-phase service who need to distribute power to multiple C13/C19 devices and check current on each phase locally.
- Rack builders who want a 0U vertical PDU to add many power outlets without using horizontal rack space.
- IT teams powering a mix of 208V rack equipment and a smaller number of 120V devices, using the PDU’s C13/C19 and NEMA outlets.
- Technicians who need a local, at-the-rack view of input current by phase when checking or balancing a three-phase load.
Real-World Use Scenarios
- In a data-center rack with a compatible 208V three-phase feed, an operator can power a mix of 208V servers and 120V network or support equipment from one vertical PDU; the different outlet types help accommodate both without adding a separate distribution strip.
- When commissioning or adding equipment to a rack, a technician can check the built-in meters for current on each input phase and spot an uneven load before continuing; the meters show phase-level current, not per-outlet consumption.
- In a heavily populated rack, the vertical 0U installation keeps the PDU out of the equipment mounting spaces, leaving rack units available for servers and switches while providing outlets along the rack.
- For a rack with multiple dual-power-supply servers, an operator can connect equipment power cords to available outlets and use the retention brackets to help keep plugs seated; this PDU provides one input feed, so it does not by itself create A/B power redundancy.
- When planning power for a colocation or server-room rack, a facilities team can use the per-phase readings to check the rack’s current draw against its planned capacity; the readings can inform load checks but do not remotely monitor or control individual outlets.
Spec Summary
| Attribute | Value |
|---|---|
| Best For | Three-phase datacenter configurations and heavily equipped network racks |
| Power Rating And Metering | Metered 3-phase PDU rated at 5.7 kW; the catalog also lists 5.7 kVA total. Three built-in current meters report input current per phase |
| Input And Output | 208V input via a NEMA L21-20P plug, with a 6 ft cord. Provides 48 outlets across three single-phase load banks: 36 C13 and 6 C19 outlets at 208V, plus 6 NEMA 5-15/20R outlets at 120V. Output frequency: 60 Hz |
| Rack Mounting | 0U vertical rackmount design, 70 in. high, for 2- or 4-post racks; supports toolless button mounting in compatible racks or mounting brackets |
| Dimensions And Weight | 70 × 1.93 × 2.2 in. (H × W × D); 12.6 lb |
| Certifications And Operating Environment | Tested to UL60950-1 (USA and Canada); NOM (Mexico), Class A emissions, and RoHS. Operating relative humidity: 0–95% |
| Model Identifiers | Tripp Lite PDU3MV6L2120 |