    180W 24V 6.5A Universal AC UPS/Charge Function Monitor Switching Power Supply Input 110/220v Battery Charger Output 24VDC

    • 1.AC input selectable by switch
    • 2.Protectionsshort circuit/overload/over voltage
    • 3.Cooling by free air convection 100% full load burn-in test
    +
    +
    Overview
    Specs
    Reviews
    New 180W 12V 13.5A universal AC UPS/Charge function monitor switching power supply input 110/220v battery charger output 12VDC
    Battery type is not required, lead, lithium and other batteries all can charge.
    The power supply had no request for the battery "Amp", big battery capacity charge time long, small capacity charge fast.
    Specification:
    Model
    SC-180-12
    SC-180-24
    output
    DC voltage
    CH1:12V
    CH2:13.8V
    CH1: 24V
    CH2:27.6V
    Voltage tolerance
    ±2%
    -----
    ±1%
    -----
    Rated current
    13.5A
    1.5A
    6.5A
    1A
    Current range
    0~15A
    -----
    0~7.5A
    -----
    Rated power
    182.7W
    182.7W
    Ripple&noise
    120mvpp
    --
    180mvp-p
    -----
    DCvoltage ADJ.range
    CH1:10.3~13.8V
    CH1:21.3~27.5V
    input
    Voltage range
    90~132VAC/ 180VAC~264VAC Select by switch ,237~370VDC
    frequency
    47~63HZ
    AC current
    2.8A/115VAC,1.4A/230VAC
    efficiency
    81%
    83%
    Inrush current
    Cold start current 30A/115VAC,50A/230VAC
    Leakage current
    <; 1mA/240VAC
    protection
    Over load
    Rated output power110%~150% start over load protection
    protection mode: AC charging mode:hiccup mode auto-recovery after fault condition is removed
    Battery protection
    At low voltage
    9.5~11V
    20~22V
    protection mode:cutoff output
    Function
    UPS introduction
    long-term online floating charge to battery,high charging efficiency,battery can saturate to more than 90% ,cauto-stop charging when it's full,prevent over charging. Effectively extend battery life,AC/battery auto switch,no switch time,no need human guard,
    cold-start ,when there is no AC input ,can use battery start UPS,Meet the user's emergency needs
    safety
    Withstand voltage
    I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
    Isolated resistance
    I/P-O/P,I/P-FG,O/