Your Browsing History







Other Useful Features
Ergonomic design fits in your hand and can be used while wearing personal protective equipment
Large, easy-to-read backlit display improves readings in low light settings
Connects to your smartphone via Fluke Connect so you can read measurements at a safer distance
Measures AC current to 600 A and AC and DC voltage to 600 V
Measures capacitance to 1000 µF and DC current to 200 µA
Measures temperature from -10 °C to 400 °C (14 °F to 752 °F)
Offers True-RMS voltage and current measurements to accurately measure non-linear signals
Measures resistance to 60 k
Offers Min/Max recording to capture variations automatically
Runs on two AA alkaline batteries
Specifications
| Function | |||
| A ac (via Jaw) | |||
| Resolution | 0.1 A | ||
| Accuracy | 2.0% ±5 digit (45-65 Hz) | ||
| 2.5% ±5 digit (65-400 Hz) | |||
| Range | 600.0 A | ||
| Crest Factor (50Hz or 60Hz) | 2.5 MIN@220 A | > 1.4 MIN@600 A | Add 2% for CF>400 A |
| V ac | |||
| Resolution | 0.1 V | ||
| Accuracy | 1.5% ±5 digits | ||
| Range | 600.0 V | ||
| V dc | |||
| Resolution | 0.1 V | ||
| Accuracy | 1.5% ±5 digits | ||
| Range | 600.0 V | ||
| Ohms | |||
| Resolution | 0.1/1/10 | ||
| Accuracy | 1% ±5 digits | ||
| Range | 600/6000/60.00 k | ||
| Capacitance | |||
| Resolution | 0.1/1 µF | ||
| Accuracy | 1% ±4 digits | ||
| Range | 100.0/1000 µF | ||
| µA | |||
| Resolution | 0.1 µA | ||
| Accuracy | 1% ±5 digits | ||
| Range | 200 µA | ||
| Contact temperature | |||
| Resolution | 0.1 C/F | ||
| Accuracy | 1% ±8 digits | ||
| Range | -40 to 400 °C (-40 °F to 752 °F) | ||
| Continuity beeper | |||
| Beeper volume | 75 dBA nom. 15 cm. from case front | ||
| On threshold | <=30 | ||
| Mechanical and General Specifications | |||
| Maximum voltage between any terminal and earth ground | 600 V | ||
| Battery type | 2 AA alkaline batteries, NEDA 15A, IEC LR6 | ||
| Temperature | Operating: -10 °C to +50 °C (14 °F to +122 °F) | Storage: -40 °C to +60 °C (-40 °F to +140 °F) | |
| Operating humidity | Non condensing (< 10 °C [50 °F]), 90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), 75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), 45 % RH (at 40 °C to 50 °C (104 °F to 122 °F)) | ||
| Altitude | Operating: 3,000 m (9,842 ft) | Storage: 12,000 m (39,370 ft) | |
| Dimensions | 230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in) | ||
| Weight (meter only) | 419 g (15 oz) | ||
| Safety | IEC 61010-1, Pollution Degree 2 | IEC 61010-2-032: CAT III 600 V / CAT IV 300 V | IEC 61010-2-033: CAT III 600 V / CAT IV 300 V |
| IP Rating | IEC 60529: IP30, non-operating | ||
| Radio Frequency Certification | FCC ID:T68-FBLE IC:6627A-FBLE | ||
| Electromagnetic Compatibility (EMC) | International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | ||
| Temperature coefficients | Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C |