APC Rack Mount PDU, Metered 200V-208V/30A, (42) Outlets, 0U Vertical Rackmount (AP8841)
- 200V-208V Input, Metered 1Ph 30A rackmount Power Distribution Unit
- Input: NEMA L6-30P (5.0 kW)
- Output Receptacles: Thirty-Six (36) C13 Outlets, and six (6) C19 Outlets
- 0U Vertical Mounting PDU
- Cord Length: 9.8'
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Limited Warranty period (parts): 2 years
- Limited Warranty period (labor): 2 years
- Read full details
Return Policies
- Contact Manufacturer for Assistance
- This item is covered by Newegg.ca's Manufacturer Only Return Policy.
- Read full return policy for details.
Manufacturer Contact Info
- Manufacturer Product Page
- Manufacturer Website
- Support Phone: 1-800-555-2725
- Support Website
- View other products from APC
The APC AP8841 is a metered, 30A rack PDU for 200–208V power, suited to data centers and server rooms that need to distribute power to many rack-mounted devices through 36 C13 and six C19 outlets.
Recommended For
- Data-center and colocation teams powering 200–208 V rack equipment that need remote load monitoring, historical power data, and alarm thresholds to help manage circuit capacity.
- IT operators managing distributed sites who want to check rack-level power use remotely and set alerts without being physically at each rack.
- Rack builders with many C13- and C19-powered servers or network devices who want a vertical 0U PDU to distribute power while preserving rack-unit space for equipment.
- Infrastructure teams balancing loads across a 30 A, 200–208 V rack feed who want metering for amps, volts, real power, and energy.
Spec Summary
| Attribute | Value |
|---|---|
| Best For | Metered power distribution for rack-mounted equipment with IEC C13 and C19 connections |
| Electrical Input And Output | Supports 200 V, 208 V, or 230 V input at 50/60 Hz, with 200 V or 208 V output; maximum input current is 30 A, with a 24 A regulatory derated input current |
| Outlets And Connectivity | 42 outlets with IEC 320 C13 and IEC 320 C19 connections |
| Input Connection And Cord | NEMA L6-30P input connector and 9.84 ft. cord |
| Metering And Protection | Metered power distribution with overload protection |
| Operating Environment | Operating temperature: 5–45 °C; relative humidity: 5–95%; elevation: 0–10,000 ft. (0–3,000 m) |
| Storage Environment | Storage temperature: −25–65 °C; relative humidity: 5–95%; elevation: 0–50,000 ft. |
| Physical Specifications | Black; 70.51 × 2.20 × 1.73 in.; 15.08 lb. (6.84 kg) |
| Compliance | RoHS compliant; certifications include CSA C22.2 No. 60950, IEC 60950, METI Denan, UL 60950-1, and VDE |
| Model Identifiers | APC AP8841 |